Navigate by standard.
Practical context, decision pathways, worked engineering scenarios and links between the Standards that commonly overlap on real plant and projects.
AS 3990
Mechanical equipment steelwork: scope, design basis, fatigue and the AS 3990 vs AS 4100 pathway.
Open standard guide →02AS 4100
Steel structures: limit-states design, actions, serviceability, fatigue, connections and fabrication reliability.
Open standard guide →03AS 1657
Fixed platforms, walkways, stairways and ladders: choosing a safe access route and coordinating structural design.
Open standard guide →04AS 4343
Pressure equipment hazard levels: the classification inputs, boundaries and what the result does — and does not — decide.
Open standard guide →05AS 1210
Pressure vessels: design basis, vessel class, loads, fabrication, examination, testing and lifecycle risk controls.
Open standard guide →06AS 4041
Pressure piping: scope, piping class, design conditions, flexibility, supports, fabrication, testing and change control.
Open standard guide →07AS/NZS 3788
In-service inspection of pressure equipment: inspection planning, intervals, degradation, repair and asset history.
Open standard guide →08AS 4991
Lifting devices: design duty, stability, proof loading, alternative verification, marking, inspection and repair.
Open standard guide →09AS 1418 series
Cranes, hoists and winches: how the series is structured and which part to investigate for the actual equipment.
Open standard guide →10AS/NZS 4024 series
Safety of machinery: task-based risk reduction, inherently safer design, safeguarding and safety-related controls.
Open standard guide →11AS 1668 series
Ventilation and air-conditioning in buildings: choose the right pathway for mechanical ventilation, natural ventilation, smoke control or microbial control.
Open standard guide →12AS 1668.2
Mechanical ventilation in buildings: outdoor air, exhaust, make-up air, car parks, contaminant control and existing-building assessments.
Open standard guide →13AS 1668.4
Natural ventilation of buildings: permanent openings, cross-ventilation, occupied enclosures, car parks and mixed-mode strategies.
Open standard guide →14AS 1668.1
Fire and smoke control in buildings: fire-mode fans, dampers, pressurization, shutdown, controls and commissioning.
Open standard guide →15AS/NZS 3666.1
Microbial control by design: intake location, moisture, drainage, access, cleanability and commissioning.
Open standard guide →16AS/NZS 3666.2
Microbial control in operation: maintenance programs, cooling water, service records, defects and lifecycle evidence.
Open standard guide →